parmed_converter

Conversion of a ParmEd structure into a PQForceFieldSetup.

ParmEd stores every force field in AMBER units and conventions; the conversion maps those onto the PQ energy expressions:

  • bonds and angles: PQ uses 1/2 k, AMBER k, so k is doubled;

  • proper and periodic improper torsions: PQ evaluates k (1 + cos(n phi + delta)) with the IUPAC sign of phi, AMBER k (1 + cos(n phi - delta)), so the phase changes sign;

  • Lennard-Jones: one c6/c12 pair per pair of global van der Waals types;

  • exclusions and scaled 1-4 pairs: the PQ intra non-bonded file inside a molecule, linker marks for pairs between molecules;

  • rigid three-site water (O-H, O-H and H-H bond, as tleap writes TIP3P): with SHAKE, one M-SHAKE reference geometry per moltype instead of three coupled SHAKE constraints.

Summary

Functions:

check_supported

Raises if the structure contains a term PQ cannot evaluate.

convert_structure

Converts a parametrized ParmEd structure into a PQ setup.

lj_14_factor

Returns the factor between the 1-4 and the normal Lennard-Jones well depth of the atoms (CHARMM files store the scaled 1-4 values).

Reference

check_supported(structure: Any) → None[source]

Raises if the structure contains a term PQ cannot evaluate.

Parameters:

structure (parmed.Structure) – The structure to check.

Raises:

UnsupportedForceFieldTermError – For CMAP, Urey-Bradley, harmonic impropers, AMOEBA terms, virtual sites or extra points, special 1-4 Lennard-Jones parameters and AMBER 10-12 hydrogen-bond terms.

convert_structure(
structure: Any,
shake_h: bool = False,
rcoulomb: Real = 12.0,
source: str = '',
) → PQForceFieldSetup[source]

Converts a parametrized ParmEd structure into a PQ setup.

Parameters:
  • structure (parmed.Structure) – The parametrized structure with coordinates.

  • shake_h (bool, optional) – Constrain bonds to hydrogen with SHAKE instead of a bond term, by default False. Rigid three-site water (with an H-H bond) is kept rigid with M-SHAKE instead.

  • rcoulomb (float, optional) – The Coulomb cutoff in Angstrom, used for the vacuum box of a structure without box, by default 12.0.

  • source (str, optional) – A description of the source for the file headers.

Returns:

The PQ setup.

Return type:

PQForceFieldSetup

Raises:
lj_14_factor(
structure: Any,
) → Real[source]

Returns the factor between the 1-4 and the normal Lennard-Jones well depth of the atoms (CHARMM files store the scaled 1-4 values).

Parameters:

structure (parmed.Structure) – The structure.

Returns:

The common factor epsilon_14 / epsilon, 1.0 without 1-4 values.

Return type:

float

Raises: